New Times air source heat pump(Swimming pool) uniques:
A. America Copeland Compressor
B. Titanium heat exchanger
C. Stainless steel piping inside
D. Evaporator is larger than usual size to keep its high efficiency
E. Refrigerant R407c: - ODP = 0, GWP=1610
F. 36 patents with self-developed
G. Heating in winter and cooling in summer
H. Normal operation in estra-low temperature of -15~20º C with COP1.5~2.
Technical parameters |
Model | | HLRD75-YC |
HP | | 25HP |
heating capacity | KW | 99.1 |
BTU/h | 340000 |
COP | | 4.25 |
cooling capacity | KW | 76.4 |
BTU/h | 260000 |
EER | | 2.85 |
water flow rate | L/h | 3780 |
outlet-temp | ºC | 40 |
Max outlet-temp | 45 |
Power input-heating | kw | 23.3 |
-cooling | 26.8 |
current input-heating | A | 42 |
-cooling | 48.3 |
Max power input | KW | 31.5 |
Max current input | A | 56.8 |
Power supply | V/PH/HZ | 380V~ 3N~ 50Hz |
Ambient temp | ºC | (-12 ºC~ + 43 ºC) |
Rated water pressure | Mpa | 0.2~0.6 |
Compressor type | Scroll*4 |
Net weight | kg | 680 |
Package weight | kg | 734 |
Dimension | mm | 2015×970×2025 |
Package size | mm | 2130×1150×2070 |
Refrigerant | | R 407C |
Heating: Ambient temp.(DB/WB): 7 ºC/ 6 ºC, water temp.(in/out): 30 ºC/ 35 ºC; Cooling: Ambient temp.(DB/WB): 35 ºC/ 24 ºC, water temp.(in/out): 12 ºC/ 7 ºC. |